CVE-2025-6625Active Exploitation

MEDIUMCVSS 8.7 · HIGH

Exploitation ongoing with high activity in latest observed window (1 mentions)

Immediate actions

  • Patch affected systems immediately
  • Assume compromise if assets are exposed

Recommended action window: Immediate (within 24h)

NVD description

CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific crafted FTP command is sent to the device.

4.0/ 10 priority

Sources & remediation

Weakness type (CWE)
CWE-20

Priority

MEDIUM

Exploitation

ACTIVE

PoC

NONE

Patch

AVAILABLE

Momentum

STABLE

Threat summary

  • Active exploitation appears in 1 classified signals
  • Patch or workaround signal is available
  • 2 mentions across 2 observed days
  • Momentum state: stable

What's happening

  • Active exploitation reported across 1 signal
  • Patch or workaround mentioned in 1 signal
  • Technical details provided in 2 signals
  • Peaked 1d ago at 1 mentions (2026-09-18); latest day: 1
  • 2 total mentions across 2 days

Deep dive

Activity timeline2 mentions / 2d
00111Mentions · 2026-09-18: 1Mentions · 2026-09-22: 1Active Exploitation · 2026-09-18: 1Patch / Workaround · 2026-09-22: 1Technical Details · 2026-09-18: 1Technical Details · 2026-09-22: 109-1809-22
Signal classification2 categories
Active Exploitation
150.0%
Patch
150.0%
Referenced assets2 URLs
Classification over time
DateTotalLabels
2026-09-181
Active Exploitation1
2026-09-221
Patch1
Full discourse2 posts
  • CyberWorldOps@CyberWorldOps
    Patch

    Crafted FTP command can force Schneider Electric Modicon M340 offline (CVE-2025-6625, CVSS 7.5 High). Restrict FTP, patch per CISA advisory. #ICSsecurity #OTsecurity #CVE https://cyberworldops.eu/en/crafted-ftp-command-can-knock-schneider-electric-modicon-m340-devices

    Post summary

    The post discloses a CVE causing offline impact via a crafted FTP command and explicitly advises restricting FTP and patching per a CISA advisory.

    0000029
    13 followersView on X
  • Aviatrix Threat Research Center@aviatrixtrc
    Active Exploitation

    TRC analysis shows attackers exploiting CVE-2025-6625 in Schneider Electric Modicon M340 controllers through crafted FTP commands to cause denial of service against critical infrastructure. The vulnerability impacts energy, chemical, and water systems globally. Runtime segmentation helps contain operational technology network disruption. #CriticalInfrastructure #IndustrialSecurity 🔗 Full TRC analysis: https://aviatrix.ai/threat-research-center/schneider-electric-modicon-m340-cve-2025-6625-ftp-dos-vulnerability-2025

    Post summary

    The threat research center reports that attackers are actively exploiting CVE‑2025‑6625 on Schneider Electric Modicon M340 controllers through crafted FTP commands, causing denial‑of‑service impacts on energy, chemical, and water systems worldwide. No patch or workaround is provided, though runtime segmentation is suggested as a mitigation.

    0000069
    2.0K followersView on X

Explore more