CVE-2025-7376Patch

LOWCVSS 5.9 · MEDIUM

Signal is active with 1 mentions in latest observed window

Immediate actions

  • Patch affected systems immediately

Recommended action window: Monitor and triage in normal cycle

NVD description

Windows Shortcut Following (.LNK) vulnerability in multiple processes of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric GENESIS version 11.00, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95, and Mitsubishi Electric Iconics Digital Solutions GENESIS version 11.00 allows a local authenticated attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the processes of the affected products to a target file. This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC.

0.5/ 10 priority

Sources & remediation

Weakness type (CWE)
CWE-64

Priority

LOW

Exploitation

NONE

PoC

NONE

Patch

AVAILABLE

Momentum

NONE

Threat summary

  • Patch or workaround signal is available
  • 1 mentions across 1 observed day

What's happening

  • Patch or workaround mentioned in 1 signal
  • Technical details provided in 1 signal
  • 1 total mentions across 1 day

Deep dive

Activity timeline1 mentions / 1d
00111Mentions · 2026-04-08: 1Patch / Workaround · 2026-04-08: 1Technical Details · 2026-04-08: 104-08
Signal classification1 categories
Patch
1100.0%
Referenced assets2 URLs
By indicator
Full discourse1 post
  • Syed Aquib@syedaquib77
    Patch

    ⚠️ **Vulnerability Alert:** CISA ICS Advisory: Mitsubishi Electric GENESIS64 and ICONICS Suite products (multiple ICS advisories/updates) 📅 **Timeline:** Disclosure: 2026-04-07, Patch: Multiple (see references) 🆔 **CVE-2025-14815** | 📊 CVSS: 8.8 (HIGH 🟠) | 📈 EPSS: Not Available 🆔 **CVE-2025-14816** | 📊 CVSS: 8.8 (HIGH 🟠) | 📈 EPSS: Not Available 🆔 **CVE-2025-7376** | 📊 CVSS: 5.9 (MEDIUM 🟡) | 📈 EPSS: 1.456% 🆔 **CVE-2025-0921** | 📊 CVSS: 6.5 (MEDIUM 🟡) | 📈 EPSS: 20.714% 🆔 **CVE-2024-8299** | 📊 CVSS: 7.8 (HIGH 🟠) | 📈 EPSS: 6.927% 🆔 **CVE-2024-8300** | 📊 CVSS: 7.0 (HIGH 🟠) | 📈 EPSS: 10.572% 🆔 **CVE-2024-9852** | 📊 CVSS: 7.8 (HIGH 🟠) | 📈 EPSS: 6.927% 🆔 **CVE-2023-2650** | 📊 CVSS: 3.7 (LOW 🟢) | 📈 EPSS: 99.698% 🆔 **CVE-2023-4807** | 📊 CVSS: 5.9 (MEDIUM 🟡) | 📈 EPSS: 74.338% 🆔 **CVE-2024-1182** | 📊 CVSS: 7.0 (HIGH 🟠) | 📈 EPSS: 18.210% 🆔 **CVE-2024-1573** | 📊 CVSS: 5.9 (MEDIUM 🟡) | 📈 EPSS: 47.466% 🆔 **CVE-2024-1574** | 📊 CVSS: 6.7 (MEDIUM 🟡) | 📈 EPSS: 34.105% 🛠️ **Exploit Maturity:** Not Available 📂 **Affected Versions:** GENESIS64/ICONICS Suite/MobileHMI/Hyper Historian/AnalytiX <=10.97.3, MC Works64 — all versions, GENESIS <=11.03 (varies by advisory), IoTWorX 10.95, GENESIS32/BizViz — various versions 🔧 **Fixed Versions:** GENESIS64/ICONICS Suite/MobileHMI/Hyper Historian/AnalytiX: 10.98+, GENESIS: 11.01 / 11.03+, IoTWorX: 10.96+, No fix for MC Works64/GENESIS32/BizViz — vendor mitigations 🫨 **Attack Vectors:** - Local attacker / local access required - Cleartext storage of SQL credentials in local SQLite cache and plaintext display in GUI - Windows .LNK/symbolic-link exploitation enabling arbitrary writes - DLL search-path/DLL planting (uncontrolled search path) - OpenSSL parsing via BACnet Secure Connect (remote malformed cert/MAC) - Authentication bypass via AD + automatic logon conditions - Execution with unnecessary privileges / unsafe reflection 📝 **Summary:** Multiple local (and some remote) vulnerabilities across Mitsubishi/ICONICS ICS products expose plaintext SQL credentials, enable arbitrary file writes and DLL planting, and allow authentication bypass or unsafe code execution paths. Impacts include credential disclosure, tampering, denial-of-service, and, in some cases, elevated arbitrary code execution — patch immediately where available and apply mitigations for unpatchable products. 📈 **Impact Scope:** Affects multiple Mitsubishi Electric / ICONICS products used in critical manufacturing ICS: credential disclosure, information disclosure, arbitrary file tampering/deletion, DoS, and potential code execution with elevated privileges. 🛡️ **Recommended Actions:** - Apply vendor-supplied patches immediately; isolate ICS networks, restrict remote/admin logins and enforce least privilege. - Disable/delete local cache (C:\ProgramData\ICONICS\Cache\*.sdf and C:\ProgramData\ICONICS\11\Cache\*.sqlite3), prefer Windows auth for SQL Server, harden HHSplitter.exe, and follow vendor mitigations for unpatched products. 🪢 **Related Resources:** - https://www.youtube.com/watch?v=KsZ6tROaVOQ - https://en.wikipedia.org/wiki/2 🏷 **Tags:** #Cybersecurity #ICS #MitsubishiElectric

    Post summary

    The advisory reports multiple high‑severity vulnerabilities across Mitsubishi Electric and ICONICS products, providing technical details and recommending immediate patching along with mitigations for unpatched versions.

    00000111
    276 followersView on X