CVE-2026-2404Disclosure(schneider-electric / powerchute_serial_shutdown)

LOWCVSS 5.3 · MEDIUM

Signal is active with 1 mentions in latest observed window

Immediate actions

  • Track advisory updates for patch or workaround availability

Recommended action window: Monitor and triage in normal cycle

NVD description

CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request payload.

0.0/ 10 priority

Sources & remediation

Weakness type (CWE)
CWE-116

Priority

LOW

Exploitation

NONE

PoC

NONE

Patch

NONE

Momentum

STABLE

Are you affected?

If you run products in this scope, you should treat this CVE as relevant to your environment.

  • powerchute_serial_shutdown

Threat summary

  • 3 mentions across 2 observed days
  • Momentum state: stable

What's happening

  • Technical details provided in 3 signals
  • Disclosure: 3 classified signals
  • Peaked 1d ago at 2 mentions (2026-04-19); latest day: 1
  • 3 total mentions across 2 days

Affected systems

Products
powerchute_serial_shutdown

Deep dive

Activity timeline3 mentions / 2d
01122Mentions · 2026-04-19: 2Mentions · 2026-07-10: 1Technical Details · 2026-04-19: 2Technical Details · 2026-07-10: 104-1907-10
Signal classification1 categories
Disclosure
3100.0%
Referenced assets3 URLs
Classification over time
DateTotalLabels
2026-04-192
Disclosure2
2026-07-101
Disclosure1
Full discourse3 posts
  • BREACHSPIDER@breachspider
    Disclosure

    [CVE Analysis] CVE-2026-2404: Schneider Electric PowerChute Serial Shutdown Exposes UPS-Controlled Shutdown Logic https://breachspider.com/intel/2026-07-10-cve-2026-2404-schneider-electric-powerchute-serial-shutdown #ICS #OTSecurity #SCADA #CriticalInfrastructure

    Post summary

    The text announces the disclosure of CVE‑2026‑2404 with a brief technical description, but does not provide a PoC, exploit, patch, or evidence of active exploitation.

    0000079
    2.3K followersView on X
  • Infoflowcloud@infoflowcloud
    Disclosure

    🚨*CVE* CVE-2026-2404 CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check re… https://www.cve.org/CVERecord?id=CVE-2026-2404 ----- Traducción: CVE-2026-2404 CWE… http://infoflow.cloud`

    Post summary

    The post announces the existence of CVE‑2026‑2404 with technical details about log injection, but does not mention PoC, exploitation tools, or patches.

    0000032
    72 followersView on X
  • CVE@CVEnew
    Disclosure

    CVE-2026-2404 CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check re… https://www.cve.org/CVERecord?id=CVE-2026-2404

    Post summary

    The post discloses CVE‑2026‑2404 as a CWE‑116 log injection flaw triggered by modified POST /j_security_check requests, but offers no PoC, exploit code, patch, or evidence of active use.

    00000185
    57.2K followersView on X
CPE platform detail1 entries

1 of 1 entries

PartVendorProductVersionTarget SWTarget HW
Appschneider-electricpowerchute_serial_shutdown---

Explore more