CVE-2026-24105Disclosure(tenda / ac15)

LOWCVSS 9.8 · CRITICAL

Signal is active with 1 mentions in latest observed window

Immediate actions

  • Track advisory updates for patch or workaround availability

Recommended action window: Monitor and triage in normal cycle

NVD description

An issue was discovered in goform/formsetUsbUnload in Tenda AC15V1.0 V15.03.05.18_multi. The value of `v1` was not checked, potentially leading to a command injection vulnerability if injected into doSystemCmd.

0.0/ 10 priority

Sources & remediation

Weakness type (CWE)
CWE-94

Priority

LOW

Exploitation

NONE

PoC

YES

Patch

NONE

Momentum

STABLE

Are you affected?

If you run products in this scope, you should treat this CVE as relevant to your environment.

  • ac15
  • ac15_firmware

Threat summary

  • 5 mentions across 4 observed days
  • Momentum state: stable

What's happening

  • Technical details provided in 5 signals
  • Disclosure: 5 classified signals
  • Peaked 3d ago at 2 mentions (2026-03-02); latest day: 1
  • 5 total mentions across 4 days

Affected systems

Vendors
Products
ac15ac15_firmware

2 versions affected across 2 products

Deep dive

Activity timeline5 mentions / 4d
01122Mentions · 2026-03-02: 2Mentions · 2026-03-03: 1Mentions · 2026-03-05: 1Mentions · 2026-03-06: 1Technical Details · 2026-03-02: 2Technical Details · 2026-03-03: 1Technical Details · 2026-03-05: 1Technical Details · 2026-03-06: 103-0203-0303-0503-06
Signal classification1 categories
Disclosure
5100.0%
Referenced assets4 URLs
Classification over time
DateTotalLabels
2026-03-022
Disclosure2
2026-03-031
Disclosure1
2026-03-051
Disclosure1
2026-03-061
Disclosure1
Full discourse5 posts
  • CRAC Learning - Tech@cracbot
    Disclosure

    CVE-2026-24105 (CVSS:9.8, CRITICAL) is Undergoing Analysis. An issue was discovered in goform/formsetUsbUnload in Tenda AC15V1.0 V15.03.05.18_multi. The value of `v1` was not check..https://nvd.nist.gov/vuln/detail/CVE-2026-24105 #cybersecurityawareness #cybersecurity #CVE #infosec #hacker #nvd #mitre

    Post summary

    CVE‑2026‑24105 is identified as a critical flaw (CVSS 9.8) affecting Tenda AC15V1.0’s goform/formsetUsbUnload, with the CVE currently under analysis; no PoC, exploit, patch, or active exploitation details are provided.

    0000030
    173 followersView on X
  • CRAC Learning - Tech@cracbot
    Disclosure

    CVE-2026-24105 (CVSS:9.8, CRITICAL) is Undergoing Analysis. An issue was discovered in goform/formsetUsbUnload in Tenda AC15V1.0 V15.03.05.18_multi. The value of `v1` was not check..https://nvd.nist.gov/vuln/detail/CVE-2026-24105 #cybersecurityawareness #cybersecurity #CVE #infosec #hacker #nvd #mitre

    Post summary

    CVE-2026-24105 is identified as a critical vulnerability (CVSS 9.8) affecting the Tenda AC15V1.0 model; the text only announces the issue and provides minimal technical details, with no PoC, exploit, or mitigation information available.

    0000029
    173 followersView on X
  • Vulmon Vulnerability Feed@VulmonFeeds
    Disclosure

    CVE-2026-24105 Command Injection Vulnerability in Tenda AC15V1.0 Router Firmware https://vulmon.com/vulnerabilitydetails?qid=CVE-2026-24105

    Post summary

    A command injection vulnerability (CVE-2026-24105) has been identified in Tenda AC15V1.0 router firmware, with details available on Vulmon.

    0000051
    4.0K followersView on X
  • Infoflowcloud@infoflowcloud
    Disclosure

    🚨*CVE* CVE-2026-24105 An issue was discovered in goform/formsetUsbUnload in Tenda AC15V1.0 V15.03.05.18_multi. The value of `v1` was not checked, potentially leading to a command injection… https://www.cve.org/CVERecord?id=CVE-2026-24105 ----- Traducción: CVE-2026-24105 Se … http://infoflow.cloud`

    Post summary

    The post announces CVE-2026-24105, a command injection flaw in Tenda AC15V1.0 caused by an unchecked `v1` parameter, with no mention of PoC, exploit, or patch.

    0000025
    55 followersView on X
  • CVE@CVEnew
    Disclosure

    CVE-2026-24105 An issue was discovered in goform/formsetUsbUnload in Tenda AC15V1.0 V15.03.05.18_multi. The value of `v1` was not checked, potentially leading to a command injection… https://www.cve.org/CVERecord?id=CVE-2026-24105

    Post summary

    A command injection vulnerability was identified in Tenda AC15V1.0 due to an unchecked 'v1' parameter in the goform/formsetUsbUnload endpoint.

    00000230
    56.6K followersView on X
CPE platform detail2 entries

2 of 2 entries

PartVendorProductVersionTarget SWTarget HW
HWtendaac151.0--
OStendaac15_firmware15.03.05.18--

Explore more