CVE-2026-34126Disclosure(tp-link / tapo_d100c)

LOWCVSS 7.5 · HIGH

Signal is active with 3 mentions in latest observed window

Immediate actions

  • Patch tp-link tapo_d100c systems immediately

Recommended action window: Monitor and triage in normal cycle

NVD description

TP-Link has identified a vulnerability in Tapo L535E v1.0 and v3.0, Tapo P300 v1.0, and Tapo D100C v1.0, where Bluetooth communication during the initial setup phase is transmitted in cleartext without encryption. Bluetooth is only used during initialization. An attacker within the Bluetooth range could exploit this behavior using Bluetooth sniffing or man-in-the-middle techniques, which may allow eavesdropping on Bluetooth communication, manipulate transmitted setup data and potentially gain unauthorized control of the device during initialization.  An attacker within the Bluetooth range could exploit this behavior using Bluetooth sniffing or man-in-the-middle techniques, which may allow eavesdropping on Bluetooth communication, manipulate transmitted setup data and potentially gain unauthorized control of the device during initialization. D100C is the chime delivered with your Tapo camera, and it is delivered with the following Tapo products: D130, D210, D235, D225, TD21, TDB21 and TD25

1.0/ 10 priority

Sources & remediation

Vendor / third-party advisories
Weakness type (CWE)
CWE-319

Priority

LOW

Exploitation

NONE

PoC

NONE

Patch

AVAILABLE

Momentum

STABLE

Are you affected?

If you run products in this scope, you should treat this CVE as relevant to your environment.

  • tapo_d100c
  • tapo_d100c_firmware
  • tapo_l535e
  • tapo_l535e_firmware

Threat summary

  • Patch or workaround signal is available
  • 4 mentions across 2 observed days
  • Momentum state: stable

What's happening

  • Patch or workaround mentioned in 1 signal
  • Technical details provided in 3 signals
  • Disclosure: 2 classified signals
  • General: 1 classified signal
  • Peaked at 3 mentions on most recent observed day (2026-06-05)
  • 4 total mentions across 2 days

Affected systems

Vendors
Products
tapo_d100ctapo_d100c_firmwaretapo_l535etapo_l535e_firmwaretapo_p300tapo_p300_firmware

6 versions affected across 6 products

Deep dive

Activity timeline4 mentions / 2d
01223Mentions · 2026-05-28: 1Mentions · 2026-06-05: 3Patch / Workaround · 2026-06-05: 1Technical Details · 2026-06-05: 305-2806-05
Signal classification3 categories
Disclosure
250.0%
General
125.0%
Patch
125.0%
Referenced assets4 URLs
Classification over time
DateTotalLabels
2026-05-281
General1
2026-06-053
Disclosure2Patch1
Full discourse4 posts
  • izurina@izrn_yukikaze
    Patch

    CVE-2026-34126はTP-Link社製IoT機器の初期設定時に使用されるBluetooth通信が暗号化されていなかったというものになります。通信データの中には機微情報が含まれるため、危機のファームウェアアップデートを強く推奨します。 https://cve.org/CVERecord?id=CVE-2026-34126 https://tp-link.com/jp/support/faq/5106/

    Post summary

    TP‑Link IoT devices expose sensitive information via unencrypted Bluetooth communication during initial setup; a firmware update is strongly advised to mitigate the risk.

    01031337
    2.4K followersView on X
  • しーにゃ♪@公式@Syynya
    Disclosure

    セキュリティアドバイザリ:Tapo L535E・P300・D100Cにおける初期設定時のBluetooth通信で暗号化されていない通信が使用される脆弱性(CVE-2026-34126) https://www.tp-link.com/jp/support/faq/5106/

    Post summary

    A TP‑Link security advisory alerts that Tapo L535E, P300, and D100C use unencrypted Bluetooth communication during initial setup (CVE‑2026‑34126). It contains no PoC, exploit code, or active exploitation claims, nor does it mention patches.

    0000055
    910 followersView on X
  • seeck.jp@seeckjp
    Disclosure

    セキュリティアドバイザリ:Tapo L535E・P300・D100Cにおける初期設定時のBluetooth通信で暗号化されていない通信が使用される脆弱性(CVE-2026-34126) | TP-Link 日本 https://www.tp-link.com/jp/support/faq/5106/

    Post summary

    TP‑Link Japan’s security advisory discloses an unencrypted Bluetooth communication flaw (CVE‑2026‑34126) in Tapo devices during initial setup, with no PoC, exploit code, active exploitation, or patch details mentioned in the provided excerpt.

    0000086
    16 followersView on X
  • Vulmon Vulnerability Feed@VulmonFeeds
    General

    CVE-2026-34126 Unencrypted Bluetooth Communication in TP-Link Tapo Devices During Initial Setup https://vulmon.com/vulnerabilitydetails?qid=CVE-2026-34126

    Post summary

    The snippet merely references CVE-2026-34126 and its title, with no evidence of PoC, exploit, patch, or detailed technical information.

    0000063
    4.0K followersView on X
CPE platform detail8 entries

8 of 8 entries

PartVendorProductVersionTarget SWTarget HW
HWtp-linktapo_d100c1.0--
OStp-linktapo_d100c_firmware1.3.1--
HWtp-linktapo_l535e1.0--
HWtp-linktapo_l535e3.0--
OStp-linktapo_l535e_firmware1.4.1--
HWtp-linktapo_p3001.0--
OStp-linktapo_p300_firmware1.4.0--
OStp-linktapo_p300_firmware1.4.2--

Explore more