CVE-2026-4565Disclosure(tenda / ac21)

LOWCVSS 7.4 · HIGH

Signal is active with 1 mentions in latest observed window

Immediate actions

  • Track advisory updates for patch or workaround availability

Recommended action window: Monitor and triage in normal cycle

NVD description

A vulnerability was detected in Tenda AC21 16.03.08.16. Impacted is the function formSetQosBand of the file /goform/SetNetControlList. Performing a manipulation of the argument list results in buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.

0.0/ 10 priority

Sources & remediation

Weakness type (CWE)
CWE-119CWE-120

Priority

LOW

Exploitation

NONE

PoC

YES

Patch

NONE

Momentum

STABLE

Are you affected?

If you run products in this scope, you should treat this CVE as relevant to your environment.

  • ac21
  • ac21_firmware

Threat summary

  • 7 mentions across 3 observed days
  • Momentum state: stable

What's happening

  • Technical details provided in 4 signals
  • Disclosure: 5 classified signals
  • General: 1 classified signal
  • Peaked 1d ago at 5 mentions (2026-03-23); latest day: 1
  • 7 total mentions across 3 days

Affected systems

Vendors
Products
ac21ac21_firmware

2 versions affected across 2 products

Deep dive

Activity timeline7 mentions / 3d
01345Mentions · 2026-03-22: 1Mentions · 2026-03-23: 5Mentions · 2026-03-24: 1Technical Details · 2026-03-23: 3Technical Details · 2026-03-24: 103-2203-2303-24
Signal classification3 categories
Disclosure
571.4%
Disclo
114.3%
General
114.3%
Referenced assets7 URLs
Classification over time
DateTotalLabels
2026-03-221
Disclosure1
2026-03-235
Disclo1Disclosure3General1
2026-03-241
Disclosure1
Full discourse7 posts
  • CVEarity@CVEarity
    Disclosure

    ⚡ New CVE Alert: CVE-2026-4565 📊 Severity: 8.8 🚨 Risk Level: High 🧩 Affects: Multiple / Unspecified Products Reference: https://nvd.nist.gov/vuln/detail/CVE-2026-4565 #CVE-2026-4565 #CVE #High  #CyberSecurity #InfoSec https://t.co/Gx0iY76vnq

    Post summary

    The tweet announces CVE-2026-4565, noting its high severity (8.8) and a risk level of high, but does not provide a PoC, exploit code, evidence of active exploitation, or patch information.

    0000019
    111 followersView on X
  • RedPacket Security@RedPacketSec
    General

    CVE Alert: CVE-2026-4565 - Tenda - AC21 - https://www.redpacketsecurity.com/cve-alert-cve-2026-4565-tenda-ac21/ #OSINT #ThreatIntel #CyberSecurity #cve-2026-4565 #tenda #ac21

    Post summary

    A brief CVE alert tweet linking to an external page for CVE-2026-4565 on Tenda AC21; no PoC, exploit, patch, or detailed technical info is provided in the tweet.

    0000046
    3.6K followersView on X
  • CVE@CVEnew
    Disclosure

    CVE-2026-4565 A vulnerability was detected in Tenda AC21 16.03.08.16. Impacted is the function formSetQosBand of the file /goform/SetNetControlList. Performing a manipulation of the … https://www.cve.org/CVERecord?id=CVE-2026-4565

    Post summary

    A new vulnerability (CVE-2026-4565) has been identified in the Tenda AC21 firmware, specifically affecting the formSetQosBand function within /goform/SetNetControlList.

    0000083
    56.8K followersView on X
  • CyberDudeBivash® | Global Cybersecurity Company@cyberbivash
    Disclo

    🚨 CYBERDUDEBIVASH SENTINEL APEX ALERT 🚨 Threat: CVE-2026-4565 - Tenda AC21 SetNetControlList formSetQosBand buffer overflow Intel Report: https://ift.tt/awN2o0H

    Post summary

    The alert highlights a buffer‑overflow vulnerability in Tenda AC21 (CVE-2026-4565) but offers no PoC, exploit code, or patch information.

    0000027
    289 followersView on X
  • CVEFind.com@CveFindCom
    Disclosure

    [CVE-2026-4565: HIGH] Critical vulnerability found in Tenda AC21 16.03.08.16 allows remote exploitation due to buffer overflow in formSetQosBand function. Attackers can manipulate arguments to trigger the expl...#cve,CVE-2026-4565,#cybersecurity https://cvefind.com/CVE-2026-4565

    Post summary

    The post announces CVE-2026-4565, a buffer‑overflow flaw in Tenda AC21 firmware that could lead to remote exploitation, but provides no PoC, exploit code, or patch information.

    0000052
    605 followersView on X
  • Vulmon Vulnerability Feed@VulmonFeeds
    Disclosure

    CVE-2026-4565 Buffer Overflow in Tenda AC21 Router via Remote Network Control List Manipulation https://vulmon.com/vulnerabilitydetails?qid=CVE-2026-4565

    Post summary

    The notice announces a buffer overflow vulnerability (CVE‑2026‑4565) in the Tenda AC21 router that permits remote manipulation of the network control list.

    0000049
    4.0K followersView on X
  • VulDB 🛡@vuldb
    Disclosure

    A new vulnerability with increased severity was disclosed for Tenda AC21 (CVE-2026-4565) https://vuldb.com/?id.352402

    Post summary

    A new vulnerability (CVE-2026-4565) affecting Tenda AC21 has been announced with higher severity, but the post lacks PoC, exploit details, or patch information.

    0000077
    2.1K followersView on X
CPE platform detail2 entries

2 of 2 entries

PartVendorProductVersionTarget SWTarget HW
HWtendaac211.0--
OStendaac21_firmware16.03.08.16--

Explore more