CVE-2026-6015General(tenda / ac9)

LOWCVSS 7.4 · HIGH

Signal is active with 1 mentions in latest observed window

Immediate actions

  • Track advisory updates for patch or workaround availability

Recommended action window: Monitor and triage in normal cycle

NVD description

A vulnerability has been found in Tenda AC9 15.03.02.13. Impacted is the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. Such manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

0.0/ 10 priority

Sources & remediation

Weakness type (CWE)
CWE-119CWE-121

Priority

LOW

Exploitation

NONE

PoC

YES

Patch

NONE

Momentum

STABLE

Are you affected?

If you run products in this scope, you should treat this CVE as relevant to your environment.

  • ac9
  • ac9_firmware

Threat summary

  • 3 mentions across 2 observed days
  • Momentum state: stable

What's happening

  • Technical details provided in 1 signal
  • General: 2 classified signals
  • Disclosure: 1 classified signal
  • Peaked 1d ago at 2 mentions (2026-04-10); latest day: 1
  • 3 total mentions across 2 days

Affected systems

Vendors
Products
ac9ac9_firmware

2 versions affected across 2 products

Deep dive

Activity timeline3 mentions / 2d
01122Mentions · 2026-04-10: 2Mentions · 2026-04-11: 1Technical Details · 2026-04-10: 104-1004-11
Signal classification2 categories
General
266.7%
Disclosure
133.3%
Referenced assets3 URLs
Classification over time
DateTotalLabels
2026-04-102
Disclosure1General1
2026-04-111
General1
Full discourse3 posts
  • CVEarity@CVEarity
    General

    ⚡ New CVE Alert: CVE-2026-6015 📊 Severity: 8.8 🚨 Risk Level: High 🧩 Affects: Multiple / Unspecified Products Reference: https://nvd.nist.gov/vuln/detail/CVE-2026-6015 #CVE-2026-6015 #CVE #High #CyberSecurity #InfoSec https://t.co/mzCXjMppxl

    Post summary

    The tweet simply announces the new CVE with severity and links to the NVD entry, providing no additional details or actionable information.

    0000044
    125 followersView on X
  • CVE@CVEnew
    General

    CVE-2026-6015 A vulnerability has been found in Tenda AC9 15.03.02.13. Impacted is the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. S… https://www.cve.org/CVERecord?id=CVE-2026-6015

    Post summary

    The post states that CVE-2026-6015 was found in Tenda AC9, identifying an affected function but providing no proof of concept, exploit, patch, or severity details.

    0000085
    57.0K followersView on X
  • CVEFind.com@CveFindCom
    Disclosure

    [CVE-2026-6015: HIGH] Critical security alert: Vulnerability discovered in Tenda AC9 15.03.02.13 could allow remote stack-based buffer overflow attack via manipulated argument PPPOEPassword in /goform/QuickInd...#cve,CVE-2026-6015,#cybersecurity https://cvefind.com/CVE-2026-6015

    Post summary

    The tweet alerts that CVE-2026-6015 is a high‑severity stack‑based buffer overflow in Tenda AC9 firmware 15.03.02.13 that could allow remote code execution via the PPPOEPassword argument.

    0000040
    619 followersView on X
CPE platform detail2 entries

2 of 2 entries

PartVendorProductVersionTarget SWTarget HW
HWtendaac91.0--
OStendaac9_firmware15.03.02.13--

Explore more