CVE-2026-6988Disclosure(tenda / hg10)

LOWCVSS 7.4 · HIGH

Signal is active with 2 mentions in latest observed window

Immediate actions

  • Track advisory updates for patch or workaround availability

Recommended action window: Monitor and triage in normal cycle

NVD description

A flaw has been found in Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon. This issue affects the function formRoute of the file /boaform/formRouting of the component Boa Service. This manipulation of the argument nextHop causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.

0.0/ 10 priority

Sources & remediation

Weakness type (CWE)
CWE-119CWE-120

Priority

LOW

Exploitation

NONE

PoC

YES

Patch

NONE

Momentum

NONE

Are you affected?

If you run products in this scope, you should treat this CVE as relevant to your environment.

  • hg10
  • hg10_firmware

Threat summary

  • 2 mentions across 1 observed day

What's happening

  • Technical details provided in 2 signals
  • Disclosure: 2 classified signals
  • 2 total mentions across 1 day

Affected systems

Vendors
Products
hg10hg10_firmware

2 versions affected across 2 products

Deep dive

Activity timeline2 mentions / 1d
01122Mentions · 2026-04-25: 2Technical Details · 2026-04-25: 204-25
Signal classification1 categories
Disclosure
2100.0%
Referenced assets2 URLs
Full discourse2 posts
  • Vulmon Vulnerability Feed@VulmonFeeds
    Disclosure

    CVE-2026-6988 Buffer Overflow in Tenda HG10 Boa Service formRoute Function via nextHop Parameter https://vulmon.com/vulnerabilitydetails?qid=CVE-2026-6988

    Post summary

    A buffer overflow vulnerability (CVE-2026-6988) in the Tenda HG10 Boa Service formRoute function has been disclosed with a reference link, but no PoC, exploit, or patch information is included.

    0000044
    4.0K followersView on X
  • CVE@CVEnew
    Disclosure

    CVE-2026-6988 A flaw has been found in Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon. This issue affects the function formRoute of the file /boaform/formRouting of the component Boa Se… https://www.cve.org/CVERecord?id=CVE-2026-6988

    Post summary

    The post announces a flaw in Tenda routers affecting the formRoute function within the Boa component, but it does not provide any PoC, exploit code, active exploitation evidence, or patch information.

    0000035
    57.2K followersView on X
CPE platform detail2 entries

2 of 2 entries

PartVendorProductVersionTarget SWTarget HW
HWtendahg10---
OStendahg10_firmware300001138--

Explore more