CVE-2026-9108Patch(rockwellautomation / studio_5000_logix_designer)

LOWCVSS 7.5 · HIGH

Signal is active with 1 mentions in latest observed window

Immediate actions

  • Patch rockwellautomation studio_5000_logix_designer systems immediately

Recommended action window: Monitor and triage in normal cycle

NVD description

A path traversal security issue exists within Studio 5000 Logix Designer® due to improper limitation of file paths within ACD project files. The software does not sanitize or validate file names embedded in the ACD file structure during the project opening procedure, allowing path traversal sequences to escape the intended extraction directory. If exploited, an attacker could craft a malicious ACD project file that results in arbitrary files being written to attacker-controlled locations on the file system, potentially leading to code execution.

0.5/ 10 priority

Sources & remediation

Weakness type (CWE)
CWE-22

Priority

LOW

Exploitation

NONE

PoC

NONE

Patch

AVAILABLE

Momentum

STABLE

Are you affected?

If you run products in this scope, you should treat this CVE as relevant to your environment.

  • studio_5000_logix_designer

Threat summary

  • Patch or workaround signal is available
  • 2 mentions across 2 observed days
  • Momentum state: stable

What's happening

  • Patch or workaround mentioned in 1 signal
  • Technical details provided in 1 signal
  • Disclosure: 1 classified signal
  • Peaked 1d ago at 1 mentions (2026-07-21); latest day: 1
  • 2 total mentions across 2 days

Affected systems

Products
studio_5000_logix_designer

1 version affected across 1 product

Deep dive

Activity timeline2 mentions / 2d
00111Mentions · 2026-07-21: 1Mentions · 2026-07-22: 1Patch / Workaround · 2026-07-21: 1Technical Details · 2026-07-22: 107-2107-22
Signal classification2 categories
Patch
150.0%
Disclosure
150.0%
Referenced assets2 URLs
Classification over time
DateTotalLabels
2026-07-211
Patch1
2026-07-221
Disclosure1
Full discourse2 posts
  • Aviatrix Threat Research Center@aviatrixtrc
    Disclosure

    TRC analysis shows attackers can chain path traversal (CVE-2026-9108) and authorization flaws in Rockwell Studio 5000 to execute arbitrary code and escalate privileges. Runtime segmentation helps contain post-compromise lateral movement in industrial networks. #CloudSecurity 🔗 Full breakdown: https://aviatrix.ai/threat-research-center/rockwell-automation-studio-5000-logix-designer-vulnerabilities-2026

    Post summary

    The post discloses that attackers can chain path traversal and authorization flaws in Rockwell Studio 5000 to achieve arbitrary code execution and privilege escalation, without mentioning active exploitation or a patch.

    0000057
    1.9K followersView on X
  • Windows Forum@windowsforum
    Patch

    🛠️ Studio 5000 flaws could let attackers escape project folders and run code in industrial systems. No exploitation yet—but “high complexity” isn’t a security strategy. Patch before the factory gets a surprise update. https://windowsforum.com/threads/cve-2026-9108-fix-studio-5000-project-and-code-execution-flaws.439871/?utm_source=x&utm_medium=social&utm_campaign=news_node84 #WindowsSecurity #RockwellAutomation https://t.co/lfO5V4SKH6

    Post summary

    CVE‑2026‑9108 could enable attackers to escape project folders and execute code on Rockwell Automation Studio 5000 systems. No exploitation has been reported yet, so users are advised to apply the available patch promptly.

    0000018
    1.3K followersView on X
CPE platform detail2 entries

2 of 2 entries

PartVendorProductVersionTarget SWTarget HW
Approckwellautomationstudio_5000_logix_designer---
Approckwellautomationstudio_5000_logix_designer36.00--

Explore more