In the Linux kernel, the following vulnerability has been resolved: iommu/amd: Fix ineffective error check in nested domain allocation amd_iommu_pdom_id_alloc() returns an int: a domain ID on success, or the negative errno from ida_alloc_range() when the ID space is exhausted or memory is short. amd_iommu_alloc_domain_nested() stores that return value in gdom_info->hdom_id, which is a u32, and only then tests it: gdom_info->hdom_id = amd_iommu_pdom_id_alloc(); if (gdom_info->hdom_id <= 0) { The assignment discards the sign, so -ENOSPC becomes 0xffffffe4 and the test never fires. The nested domain is then set up with a host domain ID that was never allocated, instead of the allocation failing with -ENOSPC. Keep the value in an int, test it there, and store it only once it is known to be valid, which is what the other amd_iommu_pdom_id_alloc() callers already do.
Exploitability Profile
None Observed
No active abuse flagged
Not Observed
No public PoC links extracted
Confirmed
1 patch mentions · 2 advisories
Stable
Peak 1 on Oct 13, 2026
Operational SSVC remediation guidance paired with multi-source scoring and CWE mappings.
Recommended SOC / VM Action
Monitor mention velocity for PoC drops, exploit tooling, or active exploitation inflection.
| Authority |
|---|
Triage Priority
CVSS v3.1
Source: Linux Kernel CNA

1mention
Across 1 tracked day
| Version |
|---|
| Score |
|---|
| Vector String |
|---|
CNALinux Kernel CNA | v3.1 | 7.8HIGH | CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H |
1 total mentions across 1 observed day · Peak 1 on Oct 13, 2026
Deduplicated GitHub PoCs, vendor advisories, NVD references, and researcher links.